AAVSO Reporting
The AAVSO Reporting page is used to create a
report of photometry measurements for submission to the American
Association of Variable Star Observers ("AAVSO"). This creates a
report in the AAVSO Extended Format. Details about report
submission and the extended format are available from the AAVSO at
https://www.aavso.org.
The AAVSO Report
A typical AAVSO report created by this tool is
shown below, in a Mira
Text Editor window. The AAVSO extended format uses
the # character to prefix Parameters and optional comments that are
not processed as star data. The first 6 lines provide the standard
parameters. Following this are a blank line, 3 COMMENT lines,
another blank line, and then the measurement data. This example
reports 3 target stars in 1 image. A comment line containing
information about the image is written as a comment before the star
measurements. This report was configured using the options in pages
tabbed below.
Configuring the extended Format Report
The report is configured using the 3 tabbed pages
described below. Use the [Create]
button to create the report.
Selecting Objects
Object to include in your report (targets,
standards, and check stars) are specified using the Select
Objects page as shown below. Target Objects, Standard Stars,
and Check Stars use the numbers in the Mira photometry measurements
window.
Objects to use are specified using the Object number from the
Apphot Pane. To report multiple Target Objects, you can enter numbers separated
by commas, like this: 1,2,5,12 or enter a sequence of
numbers like this: 1-10. You can also mix the two formats,
like this: 1,2,5,8-16,24.
Select Object Properties
|
Target Objects
|
Enter the list of objects to report using their
Object numbers in the
Apphot Pane.
|
Standard Star
|
If you use 1 standard star and you want to include
it in the report, enter its Object number from the
Apphot Pane. If you used more than 1 standard star,
Mira assumes you are doing ensemble photometry and automatically
creates the correct standard star report.
|
Check Stars
|
To include a check star in your report, Check this
box and enter the Object number from the
Apphot Pane. A check star is a target object that is
not a standard star. Normally, the check star is not included among
the Target Objects list.
|
Replace Notes with
Text
|
Check this box to insert the same note for each
object. The notes text is entered into the text box below. If
unchecked, Mira inserts the data from the Notes column of the Mira
photometry measurements table.
|
(notes text box)
|
Enter the text to save as notes for each
object.
|
[Create]
|
Click this button to create a report when all
pages are set as desired.
|
Entering Parameters into the Report
Parameters Properties
|
Observer Code
|
Enter your AAVSO observer code.
|
Chart ID
|
Enter the date code on the AAVSO chart used to
identify objects in the field.
|
Observation Type
|
Select the type sensor used for the observation.
The options are:
CCD: A CCD was used.
DSLR: A Digital SLR Camera was used.
PEP: Photoelectric Photometry was used.
VISDIG: Visual observations were made from Digital
images.
|
Add Comment
|
Check this box to add general comments to the
Parameter section of the AAVSO file. Enter the comments in the text
box below.
|
(comment text box)
|
Enter comments into the text box. If multiple
lines are entered, then Mira inserts multiple #COMMENT lines into
the file.
|
[Create]
|
Click this button to create a report when all
pages are set as desired.
|
Entering Report Options
The Report properties control the appearance
of the AAVSO report. The report is saved as plain text to a file,
Mira Text Editor, or the Windows clipboard. One way
to quickly view the effects of different properties is to select
Save Report to "Mira Text Editor",
set the properties on the AAVSO pages, and then click [Create] to view the result of the changes.
Report Properties
|
Save Report to
|
Select the target of the AAVSO report. You can
save it to a file, list it in a
Mira Text Editor, or copy it to the Windows
clipboard.
|
Error Source
|
Select which error type to use in the AAVSO
report. The options are taken from the column headings in the
Apphot Pane.
|
Column Separator
|
Enter the separator to use in the AAVSO report, or
select a previously used separator from the list. Usually, the
separator is the vertical bar character, "|". Do not include the
quote marks around the character you enter.
|
Blank line before each
image
|
Check this box to insert a blank line before
listing the measurements for each image.
|
Image data comment before
each image
|
Check this box to insert a line of image data as a
comment before listing the measurements for each image.
The listed properties include the file name,
coordinates, exposure time, filter, and others. Note that the
DateTimeObs value refers to the
beginning of the exposure.
|
[Create]
|
Click this button to create a report when all
pages are set as desired.
|
Note:
|
When more than 1 standard was measured, Mira
automatically inserts the word ENSEMBLE for the standard
star in the AAVSO report. If you used only 1 standard, then enter
its Object Number into the Select
Objects dialog.
|
Related Topics
Aperture Photometry
Aperture
Photometry Properties
Plot Light Curve
Apphot Pane
Photometric Error Definitions
AAVSO Report