New Features
The list below summarizes major additions and
changes to recent versions of Mira. Also see the README document
provided with the Mira installation.
NOTE: After installing a new version of
Mira, your web browser may display cached pages of an obsolete
version of the online User's Guide. This can create issues
with missing topics or lost graphics. To refresh the cache, use
Shift+F5 or Shift+Reload the first time you open the User's
Guide of a new Mira version.
Version 8.71
-
Updated the
Transfer
Function Properties dialog to include properties for the
bounding rectangle where pixels are sampled to compute the transfer
function.
-
Added the
Capture Cursor to TF command for setting the transfer
function sampling region rectangle.
-
Added the
Stack Plots at Right toggle command to the
Image Windows menu. When enabled,
Plot Windows are opened and stacked immediately to
the right of the Image Window. Another command resets the
stack origin to the top of the Image Window.
-
Added the
Reset Bars and Menus command to the mainframe menu
(active when no view window is open). This removes all of your
custom changes to command bars, toolbars, and menus.
-
Added the
Reset Docking Panes command to the mainframe menu
(active when no view window is open). This removes all of your
custom changes to the position, size, and status of docking
panes.
-
Added the Corner
Pixels option for background calculation in source
extraction by the
MExtract Module. See the
Background Properties page.
-
The
1-D Fit Package for is being developed for
interactively fitting data displayed in a
Plot Window. It is currently unfinished.
Version 8.7
This is a significant upgrade because of the
following feature:.
Version 8.67
-
Added the Ap Sum
column to the
photometry output table. This lists the sum of
values inside the object aperture, including the background signal.
It allows the magnitude to be manually calculated using an
alternative background value. This required revising some of the
text in the photometry topics; see
Magnitude Calculations and
Photometric Measurement Definitions.
-
Added the
Calibrate Linear Scale command to apply a
linear world coordinate calibration based on a mouse-drawn line.
This is also a button on the top-level Measurements Toolbar.
Fixed
Plot Window bugs:
-
The
Plot Window copy + paste always set the minimum x
value to 0.0 after pasting, instead of using the minimum X value of
all plots.
-
The
Plot Animation Bar trackbar and counter field did not
update to indicate the current plot series in animation mode.
Version 8.66
Version 8.65
This is a significant upgrade because of the new
window-level connections into the Mira Pro x64 User's Guide
as described below:
-
Added numerous help buttons that directly open
the specific help topic in the online User's Guide. See the
Getting Application Help topic in the online
User’s Guide for a description of how to open help for commands,
windows, and toolbars.
-
Implemented a Process Image Set on Immediate Mode Dialogs. The new checkbox opens with the processing
status from the top-most
Image Window. Set the checkbox as desired for the
current processing. The
Image Bar Processing button will be updated when the immediate mode
dialog closes. This new checkbox replaces the previous use of a
status message that specified the Image Window's processing state
but did not allow overriding it.
-
Fixed minor bugs in the user interface.
Version 8.624
-
Plot Measurements: Added this topic which summarizes
the tools used for quantifying data in a Plot Window.
-
Point Measurements: Removed testing code that
was accidentally retained in version 8.623.
-
Fixed several minor bugs.
Version 8.623
-
Marker Properties page of the
Star Removal package: Added a checkbox that
controls centroiding for the target star position. Uncheck this box
to prevent centroid "hopping" when the target star has a nearby
companion.
-
List COMMENT Keywords: Added minor changes to
the output and improved the documentation.
-
List HISTORY Keywords: Added minor changes to
the output and improved the documentation.
-
List Statistics Keywords: Added minor changes
to the output and improved the documentation.
-
List WCS Keywords: Added listing of the WCS status
and projection type to the output and improved the
documentation.
-
World Coordinate System: Added a description of
WCS projection types to the topic.
Version 8.622
Version 8.621
Version 8.62
-
Plot Bar: Added
World Coordinate System ("WCS") readout to the
existing (x,y) coordinate readout. The world coordinates refer to
the plot coordinates in the source image, if the plot was created
from an image.
-
Plot Bar: Added live pixel readout of image pixels in
the source image data, if the plot was created from an image. Both
the plotted Y value and the actual "Z" value in the image are
listed.
-
Plot Point Measurements: This plot window tool
was added in version 8.60. It now includes the image world
coordinates and pixel value, if the plot was created from an image.
The world coordinates and value are listed in the Notes section of the
Measurements pane.
-
Statistics Properties: Added the following
options to the dialog:
-
Standard Error of the
Mean added to the estimator options.
Standard Error of the
Mean - Clipped added to the estimator options.
Save Statistics to
Header option saves the statistics results as keywords in
the FITS image header.
-
Remove Statistics Keywords: This new command
removes all statistics keywords from the image header. It was added
to the
Image Window Measure >
Statistics submenu.
-
List Statistics Keywords: This new command
lists all statistics keywords from the headers of an image or image
set. It was added to the
Image Window menu in the Edit > List Keyword Types submenu and
theMeasure > Statistics submenu.
-
Calculate Airmass: Added option to calculate a table
of airmass for a range of date and time. The original action of
calculating it for only one of date & time remains
available.
-
Tutorial: Added
Using FITS Keywords to Analyze Image Data which
illustrates both user interface methods and a script to create a
scatter plot of image sky brightness versus Modified Julian
Date.
Version 8.60
Mira Pro x64 version 8.60 is a major upgrade with
dozens of new and improved features and a vast expansion of its
scripting capabilities.
-
Grid Controls: Added plotting, charting, Open in
Excel, Execute Script, and other analysis commands to the pop-up
menu of most
grid controls.
-
Create Pixel Mask command: Added some options
including export to text file.
-
Plot Windows
-
Plot Bar: The button commands for zooming, panning,
plot scaling and drawing were enhanced. Also added 4 new buttons
for the commands below.
Statistics Measurement and
Statistics Properties commands. These provide
17 statistical estimators and parameters for characterizing the
plot series. Both commands are available from the Measure > Statistics pull-down menu and the
Plot Bar.
Plot Point Measurements package: Added for
Plot Windows to the Measure >
Lines pull-down menu and the
Plot Bar.
Plot Line Measurements package: Added for
Plot Windows to the Measure >
Points pull-down menu and the
Plot Bar.
Go to Source Image command: For
Plot Windows generated from displayed images, this
commands selects the source
Image Window from the window stack and then displays
the source image and pixel coordinates used to generate the plot.
This command is available from the View >
Go to Source Image pull-down menu and the
Plot Bar.
Statistics
docking pane: Shows plot statistics measurements for
plot series in the Plot Window.
Mark Statistic command: Added to the
Statistics measurements pane to draw a selected
statistic in the
Plot Window.
-
Aperture Photometry package: Added several new
options added to the
Apphot Properties > Other page:
-
Import Photometry Catalog: Added
support for
world coordinates specified in (degrees,
degrees) to the existing option for (hms, dms) and (column,row)
pixel coordinates. See
Import Photometry Catalog
Photometric Zero Point: added
option to use the zero point from the image header rather than
calculate it.
Airmass: added option to use the
airmass from the image header rather than calculate it.
-
Go To Coordinates command for Image Windows:
Added support for
world coordinates specified in (degrees,
degrees) was added to the existing options for (hms,dms) and
(column,row) pixel coordinates. See
Go To Coordinates.
-
Toolbars converted to Docking Panes:
Converted 17 toolbars used for measurement and analysis packages to
docking pane toolbars. The new docking panes can be
opened, closed, tabified, and stacked. All markers and measurements
are retained if the toolbar is closed and re-opened. The following
toolbars were converted:
-
Points
Lines
Angles
Regions
Apphot
Astrometry
Star Removal
Source Extraction
Interactive Repair
Distance and Angle
Image Registration
Line Profile
Labels
Contour Plot
Interactive Contour Plot
Plot Points (new package added)
Plot Lines (new package added)
-
Angle "snap" was added to the
Lines, Distance & Angle, and Line Profile
packages for the
Image Window and the Lines package for the
Plot Window. Snapping to integral angles is
implemented by holding the SHIFT key
while drawing the line. A 45 degree snap is available for
Image Windows and a 90 degree snap is available for
Plot Windows.
-
General Properties dialog: New options were
added
-
Default line is stepped line
Open file tabs toward the left
Open docking panes on hover
Default max cell width
Script Language
Related Topics
Contents
Mira Pro x64 8.71 User's Guide, Copyright Ⓒ 2024 Mirametrics, Inc.
All Rights Reserved.
|