Transfer Function Pane
The Transfer Function Pane is used to interactively adjust the transfer function of an image. This docking pane attaches to the Image Window and is available in both horizontal and vertical formats. It may also be undocked from the window entirely. The stick-pin allows you to reduce the pane to a tab which opens and hides from the window border. The global default transfer function properties can be set using the Transfer Function Properties dialog.
Open the Transfer Function Pane from the
View > Transfer Function menu or
by clicking the button on the Image Tools
toolbar.
|
If you change settings for an Image Set, the changes may be
applied to either the active image or to the entire set, depending
on the state of the Transfer Function properties can be specified using
controls on the pane, by using equivalent properties in the
View > Transfer Function submenus,
or by using menus commands opened from the drop menu on the
|
Transfer Function Pane Properties
Sample Region |
The Sample Region selects the sampling region where the image intensity is measured for calculating the transfer function. The options are as follows: Entire Image: Samples the entire image. Cursor: Samples intensity inside the Image Cursor. Cursor Live: Samples intensity inside the Image Cursor and updates as the cursor moves. This slows cursor movement. |
Range |
The Range specifies how the intensity limits are calculated from the sample region. One of the options allows you to force the minimum and maximum to specific values. |
Stretch |
The Stretch provides options for extending the transfer function to higher or lower intensity. The options are as follows: Linear: Uses no Bias with equal Grayscale spacing between the transfer function's limiting values. Log: Extends the transfer function to greater contrast at lower intensity values. Gamma: Extends the transfer function to higher or lower intensity based on the gamma setting. A gamma less than 1 biases toward higher contrast in lower intensity, and vice versa. |
|
Check this box to selectively boost the contrast using a proprietary algorithm that enhances contrast between pixel values crowded in a narrow range, usually near the background level. This works with intensity images but not with RGB images. This feature was added to Mira Pro x64 version 8.66. See Using the Boost Transfer Function Option. |
Gamma Slider |
Sets the gamma value when Gamma stretch is selected. |
Min Z |
Specifies the minimum Z (intensity) value. This is active only when the Specify Z Stretch is selected. |
Max Z |
Specifies the maximum Z (intensity) value. This is active only when the Specify Z Stretch is selected. |
Min % |
Specifies the minimum percentile intensity. This is active only when the Percentile Stretch is selected. |
Max % |
Specifies the maximum percentile intensity. This is active only when the Percentile Stretch is selected. |
Contrast |
Specifies the contrast value when the Autoscale Stretch is selected. |
Save |
Opens the Transfer Function Properties dialog for saving the current settings as a profile for future use. |
Note |
The Transfer Function Pane does not work with RGB images. Instead, use the Palette Pane or Palette Properties dialog for RGB images. |
Choosing Transfer Function Properties
Using the Boost Transfer Function Option
Setting Application Properties
Mira Pro x64 8.73 User's Guide, Copyright Ⓒ 2024 Mirametrics, Inc.