Normalize Image


The Normalize Image command adjusts the image intensity to match a target specification, such as a specific value or a statistical intensity inside a region. A common application of this command is to match the brightness (intensity) of an image set. This dialog has two forms: a general form accessible as a menu command, and a specific form for a displayed image set that opens from the Animation Bar and processes only that specific image set. Normalize Image Set is opened only from a displayed image set; Normalize Images can take source images from an image set of files.

Normalize Image Properties

Profile [|>]

Opens the Select Source Images dialog to choose images from an image window, folder, files, name template, or a Mira File List.

[Select]

Select the source images.

Normalization Target

 

 Image

Selects normalization to a statistic computed from a reference image.

[Select]

Selects the normalization target image from an image window, folder, file, name template, or a Mira File List.

 Value

Selects normalization to a value. The value is entered in the field to the right. Use the [+] and [x] buttons to add or delete the currently displayed entry.

Image Normalization

Selects the method used to adjust the pixels during the normalization process.

Offset adds a constant to the image values.

Scale multiplies the image values.

Normalization Stat...

Click this button to open the Region Statistics dialog to set Properties for computing a region statistic on the images.

Adjust Exposure Time

Check this box to adjust the exposure time to correspond to the image intensity after normalizingScale method.

Output Pixel Type

Select the numeric pixel type in the normalized images.