Sigma Clipping the 1-D Fit


The pictures below show the effect of using sigma clipping in the 1-D Fit Package to reject data points.

The picture below shows a Row Plot from an image showing a flat background and a spike. We want to characterize the low-lying background data, but the tall peak will corrupt the fit. One way to exclude the spike from the fit is to use sigma clipping, which rejects the spike as "bad data".

generate/fit1dsigmaex1.jpg

The picture below shows the same data as above, but with the 1-D Fit Toolbar opened and configured for a 5-term fit and no sigma clipping.

generate/fit1dsigmaex2.jpg

The picture below shows the result of fitting 5 coefficients without enabling sigma clipping. The spike pulls the fit upward, causing extra ripples and making the fit useless for characterizing the data along the base.

generate/fit1dsigmaex3.jpg

For the fit shown below, the generate/btnfit1dsigmaclip.jpg was checked, then the generate/btncalculate.jpg was clicked to compute a new fit. The rejected points were changed to the turquoise color. The fit is in purple.

generate/fit1dsigmaex4.jpg

The picture below shopws a highly magnified view of previous figure about the base of the peak. Notice how the fit tracks the point data near the base of the profile. The upper and lower sigma envelope is drawn in purple above and below the fit.

generate/fit1dsigmaex5.jpg

Related Topics

1-D Fit Package

1-D Fit Toolbar

1-D Fit Properties

Using Point Deletion in the 1-D Fit